Non-contractual photographs

PhasePUR Series

Coalescing filters

Jonell Systems PhasePUR G 340 series liquid-liquid coalescer elements are designed to merge the free and entrained water present in a water-immiscible liquid, to enable its separation by gravity or by means of the filter housing internals.
These elements incorporate a pleated hydrophilic coalescing media that efficiently attracts water droplets and promotes their merging into larger drops. The PhasePUR G 340 series is compatible with most filter housings designed to accept elements of this configuration.

Request a quote Documentation

PhasePUR G 340 elements are designed for liquid-liquid coalescing processes requiring efficient separation of water or of an immiscible phase, with a choice of media suited to the temperature and pH of the fluid.

Three media are available: polypropylene (pH 2 to 14, up to 82 °C), glass microfiber (pH 6 to 9, up to 171 °C) and nylon (pH 6 to 12, up to 149 °C). Polypropylene is suited to the most aggressive media, glass microfiber to the highest temperatures.

PhasePUR G 340 elements are particularly suited for:

  • removal of amines from hydrocarbons;
  • removal of caustic soda from fuels;
  • removal of hydrocarbons from quench water;
  • removal of oil from ammonia, water and caustic soda;
  • removal of water from hydrocarbons and other immiscible liquids.
  • Pleated liquid-liquid coalescer element, Pall LCS configuration
  • Polypropylene media: maximum temperature 82 °C (180 °F), pH 2 to 14
  • Glass microfiber media: maximum temperature 171 °C (340 °F), pH 6 to 9
  • Nylon media: maximum temperature 149 °C (300 °F), pH 6 to 12
  • Drainage layer: cotton sock
  • Hardware: stainless steel
  • Available seals: Viton® or Teflon-encapsulated Viton® (TEV)
  • Outside diameter: 95 mm (3.75 in); inside diameter: 57 mm (2.25 in)
  • Available lengths: 520 mm (20.5 in) or 1,030 mm (40.5 in)
  • Available retention ratings: 1, 5 or 10 µm
  • Recommended change-out at 1 bar (15 PSID) differential pressure; maximum 5.2 bar (75 PSID)
  • Normal flow direction: inside to outside
  • SOE ends: open cap with handle and external O-ring, threaded bottom
  • Direct replacement for Pall PhaseSep and AquaSep LCS series, as well as PECO PLPC-P-4XX
  • Typical part number: JPM(media)-(length)340-(rating)-(seal)-SS, e.g. JPMP 20340-5-V-SS

    Request a quote

      Request a quote

      CATALOGUE PRODUITS