CPC AseptiQuik / HFC
Single-use assemblies
CPC sterile connectors integrated into Lifecube single-use bags and assemblies: AseptiQuik for sterile connection, HFC for sterile disconnection.
Pre-assembled sets with AseptiQuik G connector are suitable for aseptic connections outside a Grade A environment and maintain the safety of the sterile liquid.
Offered as standard on Lifecube 2D bags (option 2) and 3D bags (option 3), as well as on Lifecube SA transfer sets, Y sets and filtration sets.
- CPC AseptiQuik Sterile Connector: sterile connector; AseptiQuik G version with hose barb (HB) connection used on Lifecube assemblies
- CPC HFC Sterile Disconnect Couplings: sterile disconnect couplings
- Lifecube SA transfer sets: Lifemeta STT platinum-cured silicone tubing, AseptiQuik G at one end; Lifemeta EC connector or Tri-clamp TC25 / TC50 at the other
- Lifecube SA Y sets: three 50 cm lines on a Y fitting, AseptiQuik G on one or more ends
- Lifecube SA filtration sets: two 100 cm lines on either side of a Bricap C or L capsule filter, pre-assembled and pre-sterilized
- Assemblies supplied double-bagged, gamma-irradiated at 25–45 kGy; non-sterile autoclavable packaging also offered
- Manufactured under ISO 9001:2015 in ISO Class 4.8 / ISO 7 cleanroom; 100% leak tested
- Applications: fluid transfer between single-use systems and stainless steel installations, between different connector types or between single-use products from different brands; upstream / downstream switchover; PUPSIT system; temporary feed and filtration
- AseptiQuik G sizes listed in the brochure: 1/4″ HB, 3/8″ HB, 1/2″ HB
- Connector pressure, temperature, materials and flow rate: not specified in the Lifecube brochure (refer to the CPC manufacturer documentation)
- Tubing used on standard sets: Lifemeta STT platinum-cured silicone, hardness 60 ± 5 Shore A, not aseptically weldable / sealable
- Sterilization: gamma irradiation 25–45 kGy, dose verified per ISO 11137
- Bacterial endotoxins: < 0.25 EU/mL on aqueous extract (LAL, USP <85>)
- Particulates: eluate compliant with USP <788> (large-volume parenterals)
- Biological reactivity: USP <87> (in vitro) and USP <88> (in vivo), Class VI
- ADCF raw materials (animal-derived component free), compliant with FDA 21 CFR 177-182 (indirect food additives)
Available versions
| Connector | Function | Sizes listed | Availability in the Lifecube range |
|---|---|---|---|
| CPC AseptiQuik (AseptiQuik G) | Sterile connection | 1/4″, 3/8″, 1/2″ HB | 2D bags option 2 (2D…A part numbers), 3D bags option 3 (3D…A part numbers), SA transfer sets, Y sets and filtration sets, custom manifolds |
| CPC HFC | Sterile disconnection | Not specified | Listed among the available end connectors; no standard configuration in the brochure |