ALR
SKU : AALRB
Sterilizing-grade membranes
The ALR 0.2 µm microfiltration cartridges are designed for sterile gas filtration in pharmaceutical applications.
They incorporate a sterilizing-grade hydrophobic polyethersulfone (PES) membrane.
The Purcise ALR 0.2 µm microfiltration cartridges incorporate a sterilizing-grade hydrophobic PES membrane, designed for sterile gas filtration in pharmaceutical environments. They combine bacterial retention validated according to ASTM F838 and phage aerosol retention (LRV > 7), ensuring a level of performance that meets the strictest regulatory requirements.
- Validated sterilizing grade: retention of 10⁷ cfu/cm² of Brevundimonas diminuta (ATCC 19146) according to ASTM F838
- Phage aerosol retention: LRV > 7 with Bacteriophage Phi-X174 (ATCC 13706-B1)
- Naturally hydrophobic PES membrane
- Thermally welded construction without adhesives, minimizing extractables
- 100% integrity test before shipment (bubble point, air diffusion, water flow test)
- Full traceability: lot number and serial number engraved on each cartridge
- Validation guide available
- Compliant with FDA 21 CFR 177–182 requirements
MATERIALS
- Filter media: hydrophobic polyethersulfone (PES)
- Supports: polypropylene
- Core, cage, end caps: polypropylene
- Internal adapter support: PBT
- Seals: silicone, EPDM, fluoroelastomer, encapsulated FEP/PFA
FILTRATION CHARACTERISTICS
- Filtration rating: 0.2 µm
- Filtration efficiency: sterilizing grade (retention ≥ 10⁷ cfu/cm² B. diminuta according to ASTM F838)
- Effective filtration area (EFA): 0.80 m² (8.6 ft²) per 10″ cartridge
DIMENSIONS
- Length: 254.0 mm (10 in.) — base 10″
- Available lengths: 5″, 10″, 20″, 30″, 40″
- End cap configuration: DOE (0), 226/Flat (2), 226/Spear (7), 222/Flat (3), 222/Spear (8), 222 3-Flange bayonet/Spear (6)
OPERATING CONDITIONS
- Maximum operating pressure: 8.0 bar (116 psi) at 25 °C / 4.0 bar (58 psi) at 60 °C / 2.4 bar (35 psi) at 80 °C
- Maximum differential pressure (forward direction): 6.9 bar (100 psi) at 25 °C / 4.0 bar (58 psi) at 60 °C / 2.4 bar (35 psi) at 80 °C
- Maximum differential pressure (reverse direction): 3.0 bar (44 psi) at 25 °C / 1.0 bar (15 psi) at 80 °C
INTEGRITY TESTS (at 20 °C)
- Bubble point: ≥ 1.1 bar (16 psi) in IPA 60% / water 40%, air
- Air diffusion: ≤ 14 mL/min at 0.7 bar (10 psi) wetted with IPA 60% / water 40%
- Water Flow Test: ≤ 1.2 mL/min at 1.8 bar (26 psi)
STERILIZATION
- Steam-in-place (SIP) sterilization: 100 cycles of 30 min at 135 °C (< 0.3 bar, 5 psi)
- Autoclave: 100 cycles of 30 min at 130 °C
VALIDATIONS AND CERTIFICATIONS
- Bacterial retention: 10⁷ cfu/cm² Brevundimonas diminuta (ATCC 19146) according to ASTM F838
- Phage aerosol retention: LRV > 7 with > 1×10⁸ pfu Bacteriophage Phi-X174 (ATCC 13706-B1)
- Particulate release: compliant with USP <788> for large-volume parenteral preparations
- Non-fiber releasing: compliant with 21 CFR 210.3 (b) (6)
- Bacterial endotoxins: < 0.25 EU/mL (Amebocyte Lysate, USP <85>)
- USP <87> Cytotoxicity: compliant
- USP <88> Biological reactivity: compliant, Class VI-121 °C
- FDA Indirect Food Additive: compliant with 21 CFR 177–182
QUALITY TRACKING
- Full traceability by lot number and serial number
- 100% integrity test before shipment
- Individual certificate of conformity
- Laser marking of the lot number on each cartridge
- Manufactured in an ISO Class 8 clean zone
- Quality system compliant with ISO 9001:2015 and cGMP